CLEANING MEDIA AND MEDIA STATIONS




Media

Drive Casework
Compact Drive CX.0001002, SXR Capture Drive CDX-37018, CDX-37019, CDX-37020, CDX-37021, XR Capture Drive CDX-3730.

Clean all outer case work with 70% IPA lint-free wipes. Wipe gently, especially over any serial labels.



Drive Connectors
Compact Drive CX.0001002, SXR Capture Drive CDX-37018, CDX-37019, CDX-37020, CDX-37021, XR Capture Drive CDX-3730.

For cleaning the connector we recommend using an air duster only to avoid damage to connector pins. If a cleaning solvent is required, then please apply 70% IPA to a soft brush before gently cleaning the connector pins. Allow to air dry thoroughly before loatodionglt tiphe media into a camera or reader.



Adapters
Compact Drive Adapter CX.0001009

Clean all outer case work with 70% IPA lint-free wipes. Wipe gently, especially over any serial labels.






Media Stations

Compact Drive Reader USB-C CX.0001005
Clean all outer case work with 70% IPA lint-free wipes. Wipe gently, especially over any serial labels.

Compact Drive Dock TB3 CX.0001007 and SXR Capture Drive Dock TB2/TB3 CDX-75013, CDX-75014, CDX-75013-1
Clean all outer case work with 70% IPA lint-free wipes. Wipe gently. Extensive rubbing could cause deterioration of paintwork.

XR Capture Drive Dock CDX-7510, CDX-7513, CDX-75002
Clean all outer case work with 70% IPA lint-free wipes. Wipe gently. Extensive rubbing could cause deterioration of paintwork.






Power Supplies and Cables

PSU Plastic Casing
Disconnect the PSU from any power source. Clean the plastic casing with 70% IPA lint-free wipes. Wipe gently, especially over any serial labels.

PSU Cables
Disconnect from any power source. Clean only with a cloth dampened with water and mild detergent. Some cable materials may be adversely affected by IPA. Dry thoroughly with a disposable hand towel. Never submerge cables in any liquids.

Ensure no water enters the PSU cable connectors. If you are concerned that water has entered:

  • Seek a replacement.
  • To dry the cables please leave in a warm dry place for a minimum of 2 days.

Ensure cables are fully dried before use.

Thunderbolt and USB cables
Clean only with a cloth dampened with water and mild detergent. Some cable materials may be adversely affected by IPA. Dry thoroughly with a disposable hand towel..

Never submerge cables in any liquids.

Ensure no water enters the cable connectors. If you are concerned that water has entered:

  • Seek a replacement.
  • To dry the cables please leave in a warm dry place for a minimum of 2 days.

Ensure cables are fully dried before use.






Important Information

70% IPA lint-free wipes contain Isopropyl Alcohol. Please ensure that all instructions and safety guidelines provided with the wipes are followed